Cooling · Vendor directory

Data center cooling companies: an unranked directory by equipment type

These are 26 companies whose own websites say they make data center cooling equipment, grouped by what they make: room and plant equipment (CRAHs, fan walls, chillers), direct-to-chip liquid cooling (cold plates and CDUs), rear-door heat exchangers, and immersion. Nothing is ranked, no company paid to be listed, and every description and ownership change was rechecked on each company's own site on November 27, 2026. Use the capability table and vendor checklist to build a shortlist, or send one request and we'll try to route it to up to three suppliers or installers. Still choosing an approach? Compare direct-to-chip, rear-door and immersion cooling first.

Updated · How we research

How this directory was built

We started from the US Google results for “data center cooling companies” and “data center liquid cooling companies” on November 26, 2026, and the manufacturers those pages name most often. We kept a company only if its own website, or its parent's, describes data center cooling products, and we read those pages that day and again on November 27, 2026. Each description quotes or paraphrases them, and every ownership change comes from the buyer's or the company's own announcement. A “Yes” in the capability table means we found that product type on the company's site; a dash means we didn't find it there, not that the company doesn't offer it. Product claims are the companies' own and we haven't tested any equipment. Companies we found but didn't fully check this round, including Alfa Laval, Asperitas, DCX and Delta Electronics, are left off for now.

No company paid to be listed, and Data Center Service Providers has no referral, advertising or partnership agreement with any company on this page. See our referral disclosure and editorial policy.

Which kind of cooling company do you need?

Start with the part of the heat path you're buying, because few companies make every part. Heat leaves IT equipment by air or by liquid, and both paths end at the same plant: a facility water loop and the chillers, dry coolers or towers that reject heat outdoors. The diagram shows where each equipment category sits.

Where each kind of cooling equipment sits in the heat path Two paths carry heat from IT equipment to a shared plant. Air path: server fans push hot air, an optional rear-door heat exchanger can catch it at the rack, and room or row units (CRAH, fan wall, in-row) move it into water. Liquid path: cold plates on chips or immersion tanks pass heat to a technology cooling system loop, which a CDU, with its pumps and heat exchanger, couples to facility water. Both paths end at the facility water system and the chillers, dry coolers and towers that reject heat outdoors. AIR PATH LIQUID PATH IT rackhot exhaust air Cold plateor immersion tank Rear-door HXoptional, at rack TCS loopcoolant to chips CRAH · fan wallroom or in-row CDUpumps and HX Facility water system (FWS)water loop shared by both paths Chillers · dry coolers · towersreject heat outdoors
Simplified. HX = heat exchanger; TCS = technology cooling system, the loop between the CDU and the chips. CRAC units use refrigerant (DX) instead of facility water. Rear doors can be fed from a CDU, as Vertiv's CDU pages describe,24 and immersion systems also hand heat to a CDU; Submer offers single or dual CDUs on its SmartPod EVO.46 ASHRAE's W classes describe the facility water temperature in the last two boxes.1
Data center cooling equipment categories in this directory: what each does and how many listed companies show it on their own sites (checked November 27, 2026)
CategoryWhat it doesFirst question to askCompanies listing it
Room and row air unitsCRAHs (chilled water), CRACs (refrigerant), fan walls and in-row units move server exhaust air across coilsSensible capacity at your return-air temperature and airflow10
Chillers and heat rejectionChillers, dry coolers, evaporative and free-cooling units reject heat from the facility water loopCapacity and power at your design ambient and water temperature10
CDUsSeparate the facility water from the technology cooling loop and pump coolant to racksCapacity at your facility water temperature and approach18
Cold plates / direct-to-chipPlates on CPUs and GPUs carry heat into the loop; single-phase water/glycol or two-phase fluidWhich server platforms are supported, and by whom9
Rear-door heat exchangersA water coil on the back of the rack takes heat out of the exhaust air before it reaches the roomkW removed per rack at your water temperature and server airflow6
ImmersionServers sit in, or are sealed with, dielectric fluid that carries heat to a heat exchangerFluid type, server compatibility and kW per tank or chassis5

What each company's own site lists

This table is the directory in one view: 26 companies, the group they're filed under, and the equipment types we found on their own sites. Click a name to jump to its entry and links.

Data center cooling companies by equipment type, from each company's own website (checked November 27, 2026; alphabetical within group, not ranked)
CompanyGroupAir unitsChillers and heat rejectionCDUsCold plates / DTCRear doorsImmersionSource
AAON (BASX)Air and plantYes–––––4
Airedale by ModineAir and plantYesYesYes–––56
CarrierAir and plant–YesYes–––8
Daikin AppliedAir and plant–YesYes–––910
Johnson Controls (Silent-Aire, YORK)Air and plantYesYesYes–––111213
Mitsubishi Electric (CritiCool)Air and plantYesYes––––14
MuntersAir and plantYesYesYes–––15
Nortek Data Center CoolingAir and plantYes–Yes–––1617
Schneider Electric (Uniflair)Air and plantYesYesYesYesYes–1819
STULZAir and plantYes–Yes–––20
TraneAir and plantYesYesYes–––21
VertivAir and plantYesYesYesYesYesYes232425
AccelsiusDirect-to-chip and CDUs–––Yes––27
Boyd Thermal (Eaton)Direct-to-chip and CDUs––YesYes––29
ChilldyneDirect-to-chip and CDUs––YesYes––3110
CoolIT SystemsDirect-to-chip and CDUs––YesYes––32
JetCool (Flex)Direct-to-chip and CDUs––YesYes––3435
LiquidStack (Trane Technologies)Direct-to-chip and CDUs––Yes––Yes3622
nVentDirect-to-chip and CDUs––Yes–Yes–37
ZutaCoreDirect-to-chip and CDUs–––Yes––38
Motivair (Schneider Electric)Rear doors–YesYesYesYes–3940
RittalRear doors––Yes–Yes–42
USystems (ColdLogik)Rear doors––––Yes–43
GRC (Green Revolution Cooling)Immersion–––––Yes44
IceotopeImmersion–––––Yes45
SubmerImmersion–––––Yes46

“Yes” = the product type appears on the company's own site or its parent's. “–” = we didn't find it there. Air units = CRAH, CRAC, fan wall or in-row. DTC = direct-to-chip.

Shortlist builder

Filter
Equipment you're buying

Companies matched

–

Tick at least one equipment type.

How it works: the builder reads the capability table above and lists every company with a “Yes” in any (or every) column you tick, then assembles the matching questions from the vendor checklist below. Example: ticking cold plates and rear doors with “every selected type” returns Motivair, Schneider Electric and Vertiv. It only knows what we found on company websites, so treat a short list as a starting point, not a complete market.

Air-side and plant equipment makers

These 12 companies list room and row air units, chillers and heat rejection, or both, and most now list CDUs as well. They're the usual starting point for a new hall, a CRAH or chiller replacement, or a hybrid hall that mixes air and liquid.

AAON (BASX)

Air units

AAON's data center page presents its BASX line: DCF fan coil walls, which it describes as “designed for perimeter gallery thermal management,” computer room air handlers (CRAHs) with chilled water, DX and water/glycol options, and direct evaporative cooling units.4

Airedale by Modine

Air units · Chillers and heat rejection · CDUs

Airedale says its data center portfolio “includes data center chillers, CRAHs/CRACs, fan walls, in-row coolers,” backed by its IQity controls software.5 Its CDU range, extended with a skid-based design in October 2025, spans “from 400kW up to 2MW and beyond, at a 4K approach.”6 Parent company Modine's shareholders approved renaming it Modexus Solutions in November 2026.7

Carrier

Chillers and heat rejection · CDUs

Carrier's data center page lists AquaEdge and AquaForce air-cooled chillers, AquaEdge water-cooled centrifugal chillers, and Carrier coolant distribution units for direct-to-chip liquid cooling, plus lifecycle service for data center thermal systems.8

Daikin Applied

Chillers and heat rejection · CDUs

Daikin Applied lists magnetic-bearing, free-cooling and high-ambient data center chillers, and names Alliance Air Products, DDC Solutions and Chilldyne as acquisitions that broaden its range “from chip to facility.”9 Daikin's November 2025 release describes Chilldyne's CDU technology as a negative-pressure system.10

Johnson Controls (Silent-Aire, YORK)

Air units · Chillers and heat rejection · CDUs

Its data center page describes Silent-Aire, “a Johnson Controls company,” as specializing in modular data centers and CRAC and CRAHU systems.11 Silent-Aire CDUs, launched in September 2025, range “from 500kW to over 10MW” for in-row or white-space perimeter placement.12 Johnson Controls also sells YORK data center chillers such as the YVAM magnetic-bearing chiller.13

Mitsubishi Electric (CritiCool)

Air units · Chillers and heat rejection

Mitsubishi Electric's US critical-facilities site lists the MECH-iC, “a compact, oil-free centrifugal chiller system engineered for warm-water operation,” the MEWALL thermal wall, and a packaged wall-mounted DX system for containerized IT. The CritiCool line is sold through Mitsubishi Electric Critical Power Solutions.14

Munters

Air units · Chillers and heat rejection · CDUs

Munters Data Center Technologies lists chillers, CDUs, CRAHs, dry coolers and liquid cooling, and says its portfolio “supports air, liquid and hybrid architectures.” Its case studies include Oasis indirect evaporative cooling.15

Nortek Data Center Cooling

Air units · CDUs

Nortek names StatePoint, ServerCool and FANWALL as its data center cooling technologies.16 Its site announces a skidded CDU configurable from 1 MW to more than 5 MW, and describes the company as part of Madison Air.17

Schneider Electric (Uniflair)

Air units · Chillers and heat rejection · CDUs · Cold plates / DTC · Rear doors

Under its Uniflair range, Schneider lists air-cooled, free-cooling and water-cooled chillers, perimeter room cooling, and chilled-water and DX in-row units.18 Its US liquid cooling page lists CDUs, direct-to-chip systems and rear door heat exchangers, and its links for those products lead to the site of Motivair, which Schneider controls (see Motivair below).19

STULZ

Air units · CDUs

STULZ USA lists CyberAir chilled-water and DX units, the CyberWall air handler, CyberRow in-row units and the CyberCool CDU USA, and describes its range as computer room air conditioners, air handlers and humidity control for data centers.20

Trane

Air units · Chillers and heat rejection · CDUs

Trane's data center pages list data center chillers, air handlers, controls and liquid cooling systems, and describe its chillers, CDUs and controls working as one system.21 Its parent, Trane Technologies, completed its acquisition of LiquidStack in March 2026 (listed below).22

Vertiv

Air units · Chillers and heat rejection · CDUs · Cold plates / DTC · Rear doors · Immersion

Vertiv's thermal catalog covers rack, room and in-row cooling, heat rejection, outdoor packaged systems, evaporative free cooling and free-cooling chillers.23 Its CoolChip CDUs run from 70 kW to 2,300 kW in in-rack, in-row and perimeter designs,24 and Vertiv says its “thermal chain” includes direct-to-chip cooling, immersion cooling and rear-door heat exchangers.25 In December 2023 Vertiv agreed to acquire CoolTera, a UK maker of CDUs, secondary fluid networks and manifolds.26

Direct-to-chip liquid cooling: cold plates and CDUs

These 8 companies center on liquid delivered to the chip: cold plates, CDUs, or two-phase systems. Cold plates often arrive inside the server; CoolIT, for example, says server platforms from major OEMs are equipped with its cold plates.32 Ask your server vendor which plates and CDUs are qualified for your platform before you shortlist.

Accelsius

Cold plates / DTC

Accelsius makes NeuCool, a two-phase direct-to-chip cooling system; its site says it cools “4500W+ per socket.”27 Johnson Controls announced a strategic investment in October 2025,13 then led Accelsius's $65 million Series B, which closed in January 2026 with Legrand also investing.28

Boyd Thermal (Eaton)

CDUs · Cold plates / DTC

Eaton completed its acquisition of Boyd Thermal on March 12, 2026.30 Eaton's pages now list CDUs in liquid-to-liquid and liquid-to-air versions, leak-tested liquid cooling loops that combine cold plates, tubing and quick disconnects, and liquid cold plates.29

Chilldyne

CDUs · Cold plates / DTC

Chilldyne sells direct-to-chip liquid cooling built on what it calls “patented, negative pressure technology,” which it markets as leak-free.31 Daikin Applied announced its acquisition of Chilldyne on November 5, 2025.10

CoolIT Systems

CDUs · Cold plates / DTC

CoolIT lists a “full product line of liquid-to-liquid and liquid-to-air CDUs” and says server platforms from major OEMs are equipped with its cold plates.32 Ecolab completed its acquisition of CoolIT on July 2, 2026.33

JetCool (Flex)

CDUs · Cold plates / DTC

JetCool says it engineers “microchannel, microconvective, hybrid, embedded silicon” and other heat-transfer designs matched to each chip.34 Flex announced it had acquired JetCool on November 14, 2024; that release also describes a JetCool CDU for racks up to 300 kW.35

LiquidStack (Trane Technologies)

CDUs · Immersion

LiquidStack lists three CDU families: CDU 1.X, CDU 2.X and a GigaModular CDU that it says scales to multi-megawatt capacity and supports 45 °C return water.36 Trane Technologies completed its acquisition of LiquidStack on March 3, 2026; Trane's release describes LiquidStack's direct-to-chip and immersion cooling.22

nVent

CDUs · Rear doors

nVent lists CDUs, a liquid-to-air sidecar unit that supports up to two racks of liquid-cooled IT without a facility water system, and rear door heat exchangers, including an RDHX PRO it rates for racks up to 78 kW.37

ZutaCore

Cold plates / DTC

ZutaCore's HyperCool is a two-phase direct-to-chip system that removes heat at the processor “through a sealed, closed-loop system” and uses no water.38

Rear-door heat exchanger makers

These 3 companies make rear-door heat exchangers as a core product. nVent, Schneider Electric and Vertiv, listed above, also list rear doors.371925 Rear doors work with air-cooled servers, which makes them an option when a room can't take more heat but the servers aren't built for liquid.

Motivair (Schneider Electric)

Chillers and heat rejection · CDUs · Cold plates / DTC · Rear doors

Motivair lists the ChilledDoor active rear door heat exchanger, which it rates for up to 75 kW per rack, CDUs from a 4U in-rack unit up to 2.5 MW per unit, a liquid-to-air heat dissipation unit (HDU), Dynamic Cold Plates with their manifolds and quick connects, and free-cooling and air-cooled chillers.39 Its September 2025 portfolio release describes the same CDU, ChilledDoor and Dynamic Cold Plate lines.40 Schneider Electric completed the purchase of a 75% controlling stake on February 28, 2025.41

Rittal

CDUs · Rear doors

Rittal's US direct liquid cooling page lists a 70 kW rear door heat exchanger with a coolant circulation unit, a 150 kW in-rack CDU and a 1 MW in-row CDU.42

USystems (ColdLogik)

Rear doors

USystems makes ColdLogik rear door heat exchangers: the CL20 and CL23 active doors, the latter described at 200 kW per rack, and the CL21 passive door.43

Immersion cooling makers

These 3 companies make immersion systems, where dielectric fluid touches the electronics. Vertiv also lists immersion, and Trane's release describes LiquidStack's immersion cooling.2522

GRC (Green Revolution Cooling)

Immersion

GRC presents itself as a single-phase immersion cooling company and sells server immersion cooling systems for data centers, AI, HPC and edge sites.44

Iceotope

Immersion

Iceotope's “precision liquid cooling” seals a small amount of dielectric coolant inside each server chassis and passes the heat to a technology cooling system loop through a liquid-to-liquid heat exchanger. It says the design supports inlet coolant above 55 °C.45

Submer

Immersion

Submer lists the SmartPod EVO immersion system, which it rates at 140 kW+ of heat dissipation, the SmartPod EXO for higher densities, and the MicroPod edge unit with up to 7 kW.46

This list isn't complete. Mechanical contractors, manufacturers' representatives and regional integrators also install and service this equipment, and the right installer may be local to you. Companies can ask to be added or corrected by emailing requests@datacenterserviceproviders.com; see our editorial policy.

Recent acquisitions that change who you're buying from

Several liquid cooling specialists now belong to large HVAC, electrical or water companies, which can change pricing channels, service networks and warranty terms. These are the changes we confirmed from primary announcements; ask any vendor in this table who will support the equipment and honor the warranty.

Ownership and investment changes involving listed cooling companies, 2023 to 2026, from the companies' own announcements (checked November 27, 2026)
CompanyNow part ofWhat was announcedSource
JetCoolFlexAcquisition announced as done, November 14, 202435
MotivairSchneider ElectricPurchase of an initial 75% controlling interest completed February 28, 2025; Schneider expects to buy the remaining 25% in 202841
ChilldyneDaikin AppliedAcquisition announced November 5, 2025; Daikin Applied also lists Alliance Air Products and DDC Solutions among its acquisitions109
LiquidStackTrane TechnologiesAcquisition completed March 3, 2026 (announced February 10, 2026)22
Boyd ThermalEatonAcquisition completed March 12, 202630
CoolIT SystemsEcolabAcquisition completed July 2, 202633
CoolTera (UK CDU maker)Vertiv (agreement; we didn't confirm the closing)Definitive agreement to acquire announced December 4, 202326
AccelsiusNot acquired; founded by Innventure, with Johnson Controls and Legrand as investorsJohnson Controls’ “multi-million dollar strategic investment” announced October 6, 2025; $65 million Series B led by Johnson Controls, with Legrand, closed January 12, 20261328
Airedale's parent, ModineRenamed Modexus SolutionsShareholders approved the name change, announced November 16, 20267

“Now part of” reflects the announcements cited. Motivair is 75% owned until the planned 2028 purchase of the rest. We didn't verify how each brand is sold or serviced after the deal.

What to ask a cooling vendor before you shortlist

Ask every vendor to state capacity at your conditions, in writing, before you compare prices. A capacity number means little without the temperatures it was rated at. Vertiv, for example, rates its CoolChip CDUs at a stated approach temperature difference, such as 600 kW at 4 °C ATD,24 and Airedale quotes its CDU range “at a 4K approach.”6 The same unit delivers different capacity at a different approach or water temperature.

Flow matters as much as kW. Using NIST's properties for water at 30 °C (995.65 kg/m³ and 4.1798 kJ/kg·K),3 moving 600 kW with a 10 K rise across the loop takes about 865 L/min (229 gpm). At a 5 K rise it takes twice that, about 1,730 L/min. Flow is heat ÷ (density × specific heat × temperature rise), so check that each quote's pumps and pipe sizes match the temperature rise it assumes. Glycol mixtures need more flow; our coolant flow and CDU sizing calculator handles water and PG25 (25% propylene glycol).

Cooling vendor evaluation checklist: what to ask and why (sources as cited; checked November 27, 2026)
ItemAsk each vendorWhy it matters
Capacity at stated conditionsCapacity at your facility water supply temperature, loop temperature rise and approach (for CDUs), or return-air temperature and airflow (for air units); ask for the selection printoutRatings are published at specific conditions, such as 4 °C ATD for Vertiv's larger CDUs.24 Quotes rated at different conditions aren't comparable.
Water temperature classWhich ASHRAE liquid cooling class (W17, W27, W32, W40, W45 or W+) the equipment is designed for, and capacity at your warmest expected supplyASHRAE's classes set facility water supply temperatures from 17 °C (W17) to above 45 °C (W+); from W32 up, ASHRAE lists cooling towers as the primary facility, with chillers only as a supplemental option at W32 and W40.1
Efficiency data sourceWhere every efficiency or savings figure comes from: test standard, lab, conditions, baseline and date. For computer room air conditioners, whether the model is in the AHRI DirectoryAHRI certifies computer and data processing room air conditioners to AHRI Standard 1360 and/or ASHRAE 127 within its capacity scope and requires published ratings to match the AHRI Directory.2 Marketing figures, such as ZutaCore's “up to 82%” energy reduction or GRC's “up to 95% less cooling power,” need a stated baseline.3844
Fluid and water qualityRequired coolant and filtration, who supplies and tests it, and what fluid problems void the warrantyCoolant chemistry is an ongoing program, not a one-time fill. Our guide to cooling water treatment programs covers the facility side.
Redundancy and controlsRedundancy offered (N+1, N+2), what fails over automatically, and how the unit reports to your building management system (BMS) or data center infrastructure management (DCIM) softwareSome CDU lines advertise redundancy options; LiquidStack, for example, lists N+1/N+2 for its GigaModular CDU.36
Service footprintWho services the equipment in your metro (factory, dealer or contractor), where spares are stocked, and response times written into the contractSome makers service their own equipment; Munters says it designs, builds and services its systems.15 We didn't verify any company's service coverage.
Price breakdownAn itemized quote: equipment, controls, freight, startup, commissioning support, spares and any service contract priced separately, with what is excludedBundled prices hide scope differences. We don't publish prices because we didn't verify any company's pricing.
Lead timeWritten lead time, what starts the clock (purchase order or approved submittals), and whether a factory slot is reservedLead times change with demand. We didn't verify lead times for any company on this page.
Warranty termsWhen coverage starts (shipment or startup), length, parts vs labor, and how leaks or IT damage are handledLeak-related claims vary by vendor; Chilldyne, for example, markets its negative-pressure system as leak-free.31 Get the actual warranty language, not the marketing line.
Testing and commissioningFactory witness testing, startup support, and participation in integrated systems testingLiquid systems add pumps, controls and failure modes to test. See commissioning levels and integrated systems testing (IST).
Ownership and supportAfter an acquisition, who sells, services and warrants the product lineSix listed companies changed hands between November 2024 and July 2026 (see the ownership table above).

What to send cooling companies for comparable quotes

Send every company the same package so the quotes differ by approach, not by guesses about your site.

  • Site location and whether it's a new build, an expansion or a retrofit of a live hall.
  • IT load in kW or MW, rack count and kW per rack, and how much of the heat goes to liquid vs air.
  • Server or GPU platform, if liquid cooling is involved, and any cold plates or CDUs the server maker requires.
  • Facility water supply temperature (or ASHRAE W class), available flow, and whether glycol is used.
  • Climate data or design ambient temperatures, and any water-use or refrigerant limits.
  • Redundancy target (N, N+1, 2N) and the controls or building management system (BMS) the equipment must talk to.
  • Space, floor loading and access limits, plus schedule and required delivery date.
  • Scope: equipment only, or equipment plus installation, startup, commissioning and a service contract.

Using our form? Put the kW, equipment type and location in the request, along with whatever else from this list you have. You can contact companies from the directory directly, or send one request through the form on this page.

Limits of this directory

This is a snapshot from November 27, 2026. Products, ownership and brand names change; check each company's site before you rely on it. Descriptions and figures such as kW ratings are the companies' own claims, which we haven't tested, and inclusion isn't an endorsement. A dash in the capability table means we didn't find that product on the company's site, not that it isn't offered. We didn't verify US offices, service coverage, lead times, warranty terms, certifications or pricing for any company. This page is for buying equipment; it isn't investment research and says nothing about any company's stock. Nothing here is engineering advice; have a qualified mechanical engineer size and specify the system.

Get cooling quotes through Data Center Service Providers

Send one request with your location, load and the equipment you need. We review it and, where we can identify suppliers or installers that serve your area and list that equipment, share it with up to three of them. They aren't necessarily companies in the directory above. We don't have agreements with any provider yet, so we can't promise how many will respond or how quickly. Any provider that does contacts you directly, and you decide whether to hire anyone. It's free for buyers. Providers who receive requests may pay us a referral fee in future; the referral disclosure explains how. We're a referral service, not a manufacturer, contractor or engineering firm, and routing a request isn't an endorsement. Read how it works, or go to the request form.

Sources

  1. ASHRAE TC 9.9 Reference Card: 2021 Equipment Thermal Guidelines for Data Processing Environments (5th edition), ASHRAE. Liquid cooling classes W17 to W+ and their facility water supply temperatures. Checked 2026-11-27.
  2. Datacom Cooling certification program, AHRI (Air-Conditioning, Heating, and Refrigeration Institute). Program scope (AHRI Standard 1360 / ASHRAE 127) and the rule that published ratings must match the AHRI Directory. Checked 2026-11-27.
  3. Isobaric properties for water at 1 bar, 20 to 50 °C, NIST Chemistry WebBook (Standard Reference Database 69). At 30 °C: density 995.65 kg/m³, specific heat 4.1798 kJ/(kg·K). Used for the worked flow example. Checked 2026-11-27.
  4. Data Centers, AAON. Checked 2026-11-27.
  5. Edge Data Center Cooling, Airedale by Modine. Checked 2026-11-27.
  6. Airedale by Modine unveils skid-based CDU for scalable data center efficiency, Airedale by Modine, October 30, 2025. Checked 2026-11-27.
  7. Shareholders approve corporate name change to Modexus Solutions, Modine, November 16, 2026. Checked 2026-11-27.
  8. Data Center Thermal Management, Carrier Commercial. Checked 2026-11-27.
  9. Data Center Cooling Solutions, Daikin Applied. Checked 2026-11-27.
  10. Daikin Applied expands data center offering with acquisition of Chilldyne, Daikin Industries, November 5, 2025. Checked 2026-11-27.
  11. Data Centers, Johnson Controls. Checked 2026-11-27.
  12. Johnson Controls expands thermal management offering with scalable liquid cooling solution, Johnson Controls, September 8, 2025. Checked 2026-11-27.
  13. Johnson Controls announces investment in data center liquid cooling company Accelsius, Johnson Controls, October 6, 2025. Also names the YORK YVAM magnetic-bearing chiller. Checked 2026-11-27.
  14. Data Center Cooling Solutions, Mitsubishi Electric (Critical Power Solutions). Checked 2026-11-27.
  15. Munters Data Center Technologies, Munters. Checked 2026-11-27.
  16. RackBank specifies Nortek’s StatePoint cooling technology, Nortek Data Center Cooling, July 15, 2021. Names StatePoint, ServerCool and FANWALL as Nortek technologies. Checked 2026-11-27.
  17. Nortek announces 5MW CDU for liquid cooling, Nortek Data Center Cooling (repost of DatacenterDynamics), August 28, 2026. Checked 2026-11-27.
  18. Uniflair Master Range, Schneider Electric. Checked 2026-11-27.
  19. Liquid cooling solutions for AI and high-density data centers, Schneider Electric United States. Checked 2026-11-27.
  20. Data Center Cooling & Humidity Control Products, STULZ USA. Checked 2026-11-27.
  21. Data Center Cooling Solutions, Trane Commercial HVAC. Checked 2026-11-27.
  22. Trane Technologies completes acquisition of LiquidStack, Trane Technologies, March 3, 2026. Checked 2026-11-27.
  23. Thermal Management product catalog, Vertiv. Checked 2026-11-27.
  24. Vertiv CoolChip CDU, 70 to 2300 kW, Vertiv. Model table states each capacity at an approach temperature difference (ATD). Checked 2026-11-27.
  25. Vertiv expands liquid cooling portfolio in EMEA to accelerate AI-ready data centre deployments, Vertiv, May 26, 2026. Checked 2026-11-27.
  26. Vertiv acquisition of CoolTera Ltd. boosts liquid cooling portfolio, Vertiv, December 4, 2023. Announces a definitive agreement to acquire CoolTera. Checked 2026-11-27.
  27. Accelsius home page (NeuCool), Accelsius. Checked 2026-11-27.
  28. Accelsius closes $65 million Series B funding led by Johnson Controls; Legrand joining round, Innventure (founder of Accelsius), January 12, 2026. Checked 2026-11-27.
  29. Cloud data center cooling, Eaton (Boyd Thermal). Checked 2026-11-27.
  30. Eaton completes acquisition of leading liquid-cooling solutions provider Boyd Thermal, Eaton, March 12, 2026. Checked 2026-11-27.
  31. Chilldyne home page, Chilldyne. Checked 2026-11-27.
  32. Data Center Products, CoolIT Systems. Checked 2026-11-27.
  33. Ecolab has closed its acquisition of CoolIT Systems, CoolIT Systems, July 2, 2026. Checked 2026-11-27.
  34. Direct-to-Chip Liquid Cooling Technology, JetCool. Checked 2026-11-27.
  35. Flex acquires JetCool to expand data center and power portfolio, JetCool, November 14, 2024. Checked 2026-11-27.
  36. LiquidStack home page (CDU families), LiquidStack. Checked 2026-11-27.
  37. Data Center Liquid Cooling Solutions, nVent. Checked 2026-11-27.
  38. ZutaCore home page (HyperCool), ZutaCore. Checked 2026-11-27.
  39. AI & HPC Liquid Cooling Systems (products), Motivair by Schneider Electric. Checked 2026-11-27.
  40. Schneider Electric unveils liquid cooling portfolio with Motivair, Motivair by Schneider Electric, September 29, 2025. Checked 2026-11-27.
  41. Schneider Electric completes transaction to acquire Motivair Corporation, Schneider Electric, February 28, 2025. Checked 2026-11-27.
  42. Direct Liquid Cooling in Hyperscale Data Centers, Rittal (US). Checked 2026-11-27.
  43. Rear Door Heat Exchangers (ColdLogik), USystems. Checked 2026-11-27.
  44. GRC home page, GRC (Green Revolution Cooling). Checked 2026-11-27.
  45. How precision liquid cooling technology works, Iceotope. Checked 2026-11-27.
  46. Immersion cooling for computer components, Submer. Checked 2026-11-27.